Digitron 2006T Wired Digital Thermometer, Type T Probe, 1 Input(s), 350 °C Max, ±0.2°C Accuracy - SYSCAL
- N° de stock RS:
- 315-5333
- Référence fabricant:
- 2006T
- Fabricant:
- Digitron
Sous-total (1 unité)*
311,60 €
(TVA exclue)
377,04 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 311,60 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 315-5333
- Référence fabricant:
- 2006T
- Fabricant:
- Digitron
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Digitron | |
| Product Type | Digital Thermometer | |
| Maximum Temperature Measurement | 350°C | |
| Model Number | 2006T | |
| Thermometer Type | Wired | |
| Probe Type | Type T | |
| Accuracy | ±0.2°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Battery Life | 500h | |
| Length | 155mm | |
| Standards/Approvals | No | |
| Height | 40mm | |
| Width | 67mm | |
| Weight | 180g | |
| Hazardous Area Certification | No | |
| Temperature Scale | °C, Fahrenheit, F | |
| Calibrated | SYSCAL | |
| Battery Type | AA | |
| Sélectionner tout | ||
|---|---|---|
Marque Digitron | ||
Product Type Digital Thermometer | ||
Maximum Temperature Measurement 350°C | ||
Model Number 2006T | ||
Thermometer Type Wired | ||
Probe Type Type T | ||
Accuracy ±0.2°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Battery Life 500h | ||
Length 155mm | ||
Standards/Approvals No | ||
Height 40mm | ||
Width 67mm | ||
Weight 180g | ||
Hazardous Area Certification No | ||
Temperature Scale °C, Fahrenheit, F | ||
Calibrated SYSCAL | ||
Battery Type AA | ||
Statut RoHS : Exempté
Digitron 2006T Digital Thermometer
Digitron's 2006T Type T thermocouple based thermometer has been designed specifically for the food industry. Meeting the UK and International food hygiene guidelines.
Backlight
Display hold
Optional auto power off after 12 minutes
Low battery indication
Set up retention (when switched on the last settings used are displayed)
For T type thermocouples
Probes required for use with the 2006T are standard 2 pin type T thermocouples
This instrument can be calibrated with the probes listed as a system calibration. To order this calibration please use the System Cal. stock no. of the probe and the System Cal stock no. of the instrument.
Liens connexes
- Digitron 2006T Wired Digital Thermometer 1 Input(s) ±0.2°C Accuracy - UKAS
- Digitron 2006T Wired Digital Thermometer 1 Input(s) ±0.2°C Accuracy - RSCAL
- Digitron 2000T Wired Digital Thermometer 1 Input(s) ±0.5 % Accuracy - SYSCAL
- Digitron 2024T Wired Digital Thermometer 1 Input(s) ±0.2 % + 0.1°C Accuracy - SYSCAL
- Kane KM340 Wired Digital Thermometer 2 Input(s) ±0.2 % Accuracy - SYSCAL
- Kane KM330 Wired Digital Thermometer 1 Input(s) ±0.2 % Accuracy - SYSCAL
- ELC HI 935005 Wired Digital Thermometer 1 Input(s) ±0.2°C Accuracy - SYSCAL
- Hanna Instruments HI 935002 Wired Digital Thermometer 2 Input(s) ±0.2 % Accuracy - SYSCAL