Alpha Wire XTRA-GUARD 2 Control Cable, 3 Cores, 0.56mm² 20 AWG, Screened, 30 m, Black Polyvinyl Chloride Sheath

Sous-total (1 bobine de 30 mètres)*

182,56 €

(TVA exclue)

220,90 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • 127 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Bobine(s)
la bobine
le mètre*
1 +182,56 €6,085 €

*Prix donné à titre indicatif

N° de stock RS:
409-242
Référence fabricant:
25463 BK005
Fabricant:
Alpha Wire
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Alpha Wire

Product Type

Control Cable

Series

XTRA-GUARD 2

Number of Cores

3

Conductor Material

Tin Copper Wire

Jacket Material

Polyvinyl Chloride

Jacket Colour

Black

Armoured

Yes

Screened/Unscreened

Screened

Cable Length

30m

Outside Diameter

5.66mm

Voltage

300V

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

90°C

Standards/Approvals

CSA, UL, CE

Cable CSA

0.56mm²

Hazardous Area Certification

No

American Wire Gauge

20AWG

Fire Behaviour

Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1

Number of Strands

7

Core Strands

7 x 0.32mm

Size of Strands

0.32mm

Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 3 Cores - 25463 BK005


This control cable is a screened, three-core product designed for industrial signalling and control in automation and electrical systems. It is intended for installations requiring a robust, flame-retardant conductor assembly with reduced halogen emissions and a Durable outer sheath suitable for varied ambient conditions.

Features & Benefits


• Tin-plated copper conductors reduce corrosion and improve conductivity
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure

**Applications**


• Suitable for factory automation control panels and motor controllers
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required

What conductor construction is used to meet flexibility needs?


Each core comprises multiple fine strands of tin-plated copper configured as 20 AWG (7/28) to balance flexibility with electrical performance.

How is the screening implemented and what benefit does it give?


An aluminium/Mylar foil with a tinned-copper drain wire provides overall screening to reduce external electromagnetic disturbance and simplify termination to earth.

What materials form the insulation and outer sheath?


Individual cores are insulated with nominal PVC and the outer jacket is a polyurethane-specified construction that provides mechanical protection and sunlight resistance.

How does the cable behave electrically for system design?


Nominal capacitance and inductance values are provided for engineering calculations, and conductor DCR and overall shield DCR allow accurate resistance estimates for lengths.

What handling limits should be observed during installation?


Follow a minimum bend radius of 10x cable diameter and keep pull tension below the specified maximum to avoid mechanical damage.

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail