Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Lovato | |
| Product Type | Contactor | |
| Coil Voltage | 24V dc | |
| Number of Poles | 3 | |
| Contact Voltage | 440V ac | |
| Series | BF | |
| Power Rating | 7.5kW | |
| Mount Type | DIN Rail | |
| Function | Capacitor Switching | |
| Normal State Configuration | 3 NO | |
| Auxiliary Contact Configuration | 1 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Operational Current Ie | 18A | |
| Minimum Operating Temperature | -50°C | |
| Control Circuit Voltage Uc | 24V dc | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | IEC/EN 60529 | |
| Width | 45mm | |
| Length | 81mm | |
| Depth | 81mm | |
| Pole and Throw Configuration | 3PST | |
| Sélectionner tout | ||
|---|---|---|
Marque Lovato | ||
Product Type Contactor | ||
Coil Voltage 24V dc | ||
Number of Poles 3 | ||
Contact Voltage 440V ac | ||
Series BF | ||
Power Rating 7.5kW | ||
Mount Type DIN Rail | ||
Function Capacitor Switching | ||
Normal State Configuration 3 NO | ||
Auxiliary Contact Configuration 1 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Operational Current Ie 18A | ||
Minimum Operating Temperature -50°C | ||
Control Circuit Voltage Uc 24V dc | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals IEC/EN 60529 | ||
Width 45mm | ||
Length 81mm | ||
Depth 81mm | ||
Pole and Throw Configuration 3PST | ||
- Pays d'origine :
- IT
Lovato Series BF Contactor, 24V DC Coil Voltage, 18A Contact Current Rating - BF1810D024
Features & Benefits
Applications
What is the maximum temperature range for operation?
How do the coil voltage and contact ratings contribute to safety?
What type of mounting method is employed for this contactor?
What specifications should be considered for integration into existing systems?
Liens connexes
- Lovato BF Contactor 3-Pole 7.5 kW 440V ac
- Lovato BF Contactor 3-Pole 3 NO, 440V ac
- Lovato BF Contactor 3-Pole 5.5 kW 24V dc 440V ac
- Lovato BF Contactor 3-Pole 18.5 kW 440V ac
- Lovato BF Contactor 3-Pole 15 kW 440V ac
- Lovato BF Contactor 3-Pole 11 kW 440V ac
- Lovato BF Contactor 3-Pole 7.5 kW 440V ac
- Lovato BF Contactor 3-Pole 7.5 kW 440V ac