ABB GJL131 Contactor, 24V ac Coil, 3-Pole, 12 A, 5.5 kW 24V ac, 4 NO, 250 V dc, 690V ac

Sous-total (1 paquet de 5 unités)*

553,73 €

(TVA exclue)

670,015 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 03 juin 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
le paquet*
5 +110,746 €553,73 €

*Prix donné à titre indicatif

N° de stock RS:
253-4827
Référence fabricant:
GJL1311919R0101
Fabricant:
ABB
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

ABB

Coil Voltage

24V ac

Product Type

Contactor

Number of Poles

3

Contact Voltage

250, 690V dc

Contact Current

12A

Power Rating

5.5kW

Series

GJL131

Function

Motor Control

Mount Type

DIN Rail

Normal State Configuration

4 NO

Number of Auxiliary Contacts

1

Terminal Type

Solder Pin

Control Circuit Voltage Uc

24V ac

Minimum Operating Temperature

-20°C

Contactor Application

Control Unit

Operational Current Ie

12A

Maximum Operating Temperature

55°C

Standards/Approvals

UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1

Length

47.7mm

Depth

47.7mm

Width

58mm

Pole and Throw Configuration

3P

Pays d'origine :
DE

ABB GJL131 Series Contactor, 5.5kW Power Rating, 12A Operational Current - GJL1311919R0101


This contactor is a Compact electromechanical switching device designed to control three-phase motor loads in industrial control systems. It operates with a low-voltage control circuit and provides the switching capability required for motor starting and stopping within automated panels and machinery environments.

Features and Benefits:


• 24V AC Coil for integration with low-voltage control systems
• 12A operational current supporting moderate motor loads
• 3P configuration enabling three-phase switching capability
• 5.5kW power rating suitable for small to medium motors
• 690V AC maximum contact voltage for high-voltage AC circuits
• 1NO auxiliary contact delivered on a solder-pin Terminal

Applications


• Suitable for controlling three-phase motors in conveyor systems
• Ideal for panel-mounted motor starters on DIN rails
• Used with factory automation equipment requiring Compact switching
• Can be used for motor control within HVAC and pump systems

What mounting method does it use for enclosure installation?


It is designed for DIN-rail mounting to simplify installation in modular control cabinets.

What are the ambient conditions for normal operation?


The device is rated to operate between -20°C and 55°C to accommodate typical industrial indoor environments.

How many main poles does it provide for power switching?


It provides three main poles to switch each phase of a three-phase supply independently.

What international standards does it conform to for electrical switching?


It meets IEC/EN 60947 series standards as well as corresponding UL standards for industrial control switching.

What Terminal type is used for auxiliary connections?


Auxiliary connections use solder-pin terminals appropriate for PCB or wire-to-board soldering methods.

Liens connexes