ABB GJL121 Contactor, 24V Coil, 3-Pole, 20 A, 4 kW 24V, 4 NO, 690V
- N° de stock RS:
- 253-4793
- Référence fabricant:
- GJL1213911R0101
- Fabricant:
- ABB
Sous-total (1 unité)*
99,59 €
(TVA exclue)
120,50 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 99,59 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 253-4793
- Référence fabricant:
- GJL1213911R0101
- Fabricant:
- ABB
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 24V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Function | Control Unit | |
| Mount Type | DIN Rail, Wall | |
| Normal State Configuration | 4 NO | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Operational Current Ie | 20A | |
| Control Circuit Voltage Uc | 24V | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Commercial | |
| Maximum Operating Temperature | 55°C | |
| Length | 46.7mm | |
| Depth | 46.7mm | |
| Width | 96.2mm | |
| Standards/Approvals | UL, CSA | |
| Pole and Throw Configuration | 3P | |
| Sélectionner tout | ||
|---|---|---|
Marque ABB | ||
Product Type Contactor | ||
Coil Voltage 24V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Function Control Unit | ||
Mount Type DIN Rail, Wall | ||
Normal State Configuration 4 NO | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Operational Current Ie 20A | ||
Control Circuit Voltage Uc 24V | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Commercial | ||
Maximum Operating Temperature 55°C | ||
Length 46.7mm | ||
Depth 46.7mm | ||
Width 96.2mm | ||
Standards/Approvals UL, CSA | ||
Pole and Throw Configuration 3P | ||
- Pays d'origine :
- DE
ABB GJL121 Series Contactor, 20A Contact Current, 24V Coil Voltage - GJL1213911R0101
This contactor is an electromechanical switching device designed for commercial control circuits, enabling remote switching of three-phase loads in automation and electrical systems. It operates with a low-voltage control input and is intended for installation either on DIN rail or fixed to a wall, providing a Compact solution for reversing motor control and related switching tasks.
Features and Benefits:
• 24V Coil provides low-voltage control compatibility
• 3-pole arrangement handles three-phase switching tasks
• 20A operational current supports moderate motor loads
• 4kW power rating suitable for small motor drive applications
• 1NO auxiliary contact allows Basic control signalling
• Screw terminals enable secure conductor connections
• 3-pole arrangement handles three-phase switching tasks
• 20A operational current supports moderate motor loads
• 4kW power rating suitable for small motor drive applications
• 1NO auxiliary contact allows Basic control signalling
• Screw terminals enable secure conductor connections
Applications
• Suitable for reversing small three-phase motors in plant equipment
• Ideal for control panels in commercial building automation
• Used with contactor-based motor starters for facility HVAC systems
• Can be used for switching distribution loads up to 690V-rated systems
• Ideal for control panels in commercial building automation
• Used with contactor-based motor starters for facility HVAC systems
• Can be used for switching distribution loads up to 690V-rated systems
What environmental temperatures can it tolerate during operation?
It is rated to function between -20°C and 55°C, accommodating common indoor industrial and commercial environments.
How is the device mounted within a control enclosure?
It can be secured on standard DIN rail profiles or affixed directly to a wall or panel for flexible installation.
What approvals exist that relate to safety standards?
The unit meets recognised UL and CSA approvals relevant to industrial electrical equipment.
How many auxiliary contacts are available for interlock or signalling?
One normally open auxiliary contact is provided for use in control or indicator circuits.
What Terminal style is used for wiring connections?
The contact points employ screw-type terminals to ensure firm electrical and mechanical connections.
Liens connexes
- ABB GJL121 Contactor 3-Pole 4 kW 24V 690V
- ABB GJL121 Contactor 3-Pole 1.4 kW 24V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 24V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24V 690V
- ABB GJL121 Contactor 4-Pole 4 kW 24V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24V 250 V dc, 690V ac