ABB 1SBL35 Contactor, 3-Pole, 50 A, 22 kW 130V, 48 V, 3 NO, 690V
- N° de stock RS:
- 253-1997
- Référence fabricant:
- 1SBL357001R6900
- Fabricant:
- ABB
- N° de stock RS:
- 253-1997
- Référence fabricant:
- 1SBL357001R6900
- Fabricant:
- ABB
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ABB | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 50A | |
| Power Rating | 22kW | |
| Series | 1SBL35 | |
| Function | Control Unit | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 0 | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 130V, 48V | |
| Minimum Operating Temperature | -25°C | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 100A | |
| Maximum Operating Temperature | 55°C | |
| Length | 108mm | |
| Depth | 110mm | |
| Standards/Approvals | CSA C22-2 N°14, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, TR CU 001/2011 | |
| Width | 70mm | |
| Pole and Throw Configuration | 3P | |
| Sélectionner tout | ||
|---|---|---|
Marque ABB | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 50A | ||
Power Rating 22kW | ||
Series 1SBL35 | ||
Function Control Unit | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 0 | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 130V, 48V | ||
Minimum Operating Temperature -25°C | ||
Contactor Application Control Unit | ||
Operational Current Ie 100A | ||
Maximum Operating Temperature 55°C | ||
Length 108mm | ||
Depth 110mm | ||
Standards/Approvals CSA C22-2 N°14, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, TR CU 001/2011 | ||
Width 70mm | ||
Pole and Throw Configuration 3P | ||
- Pays d'origine :
- BG
ABB AF50 Series Contactor, 100A Operational Current, 22kW Power Rating - 1SBL357001R6900
Features & Benefits
• 22 kW AC-3 power rating supports medium-power motors
• 48 to 130V control range permits wide Coil supply compatibility
• 3NO main contact arrangement enables straightforward motor starters
• Screw terminals allow secure connections for conductors
• Can tolerate short control-voltage interruptions, improving uptime
Applications
• Ideal for bypass and capacitor switching in power circuits
• Used for lighting and DC power circuit control in traction systems
• Can be used for retrofit replacement of like-for-like contactors
What ambient temperatures can it operate within when fitted with an overload relay?
What insulation and impulse withstand levels does it meet for industrial environments?
How does the Coil consumption affect control wiring design?
What mechanical and electrical switching duties are supported?
Liens connexes
- ABB 1SBL35 Contactor 50 A 48 V 690V
- ABB 1SBL35 Contactor 100 A 48 V 690V
- ABB 1SBL2 Contactor 48 V Coil 50 A 48 V 690V
- ABB 1SBL17 Contactor 48 V Coil 4 A 48 V 690V
- ABB 1SBL36 Contactor 48 V Coil 100 A 48 V 690V
- ABB 1SBL2 Contactor 48 V Coil 50 A 48 V 690V
- ABB 1SBL23 Contactor 48 V Coil 26 A 48 V 690V
- ABB 1SBL27 Contactor 48 V Coil 50 A 48 V 690V