ABB AF50 Contactor, 3-Pole, 22 kW 130V, 48 V, 3 NO, 690V

Sous-total (1 unité)*

492,78 €

(TVA exclue)

596,26 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 13 octobre 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +492,78 €

*Prix donné à titre indicatif

N° de stock RS:
253-1997
Référence fabricant:
1SBL357001R6900
Fabricant:
ABB
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

ABB

Product Type

Contactor

Number of Poles

3

Contact Voltage

690V

Series

AF50

Power Rating

22kW

Function

Motor Control

Normal State Configuration

3 NO

Number of Auxiliary Contacts

0

Terminal Type

Screw

Contactor Application

Control Unit

Control Circuit Voltage Uc

130, 48V

Minimum Operating Temperature

-25°C

Operational Current Ie

100A

Maximum Operating Temperature

55°C

Standards/Approvals

CSA C22-2 N°14, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, TR CU 001/2011

Width

70mm

Length

108mm

Depth

110mm

Pole and Throw Configuration

3P

Pays d'origine :
BG

ABB AF50 Series Contactor, 100A Operational Current, 22kW Power Rating - 1SBL357001R6900


This contactor is a three-pole switching device designed to control 3-phase motors and general power circuits up to 690 V. It accepts a wide control-voltage window on AC 50/60 Hz or DC supplies, allowing the same unit to be used across varying supply conditions and in installations subject to voltage dips or brief interruptions.

Features & Benefits


• 100A rated current delivers high-load switching capacity
• 22 kW AC-3 power rating supports medium-power motors
• 48 to 130V control range permits wide Coil supply compatibility
• 3NO main contact arrangement enables straightforward motor starters
• Screw terminals allow secure connections for conductors
• Can tolerate short control-voltage interruptions, improving uptime

Applications


• Suitable for switching 3-phase motor starters in industrial panels
• Ideal for bypass and capacitor switching in power circuits
• Used for lighting and DC power circuit control in traction systems
• Can be used for retrofit replacement of like-for-like contactors

What ambient temperatures can it operate within when fitted with an overload relay?


When mounted close to a thermal overload relay it is specified for operation between -25 °C and +55 °C.

What insulation and impulse withstand levels does it meet for industrial environments?


It is rated for 1000V insulation (per IEC/EN) with an 8 kV impulse withstand voltage.

How does the Coil consumption affect control wiring design?


Holding consumption is low at 2.8 V·A while pull-in requirement is 210 V·A at maximum rated control voltage, which should be considered when sising control transformers and protection.

What mechanical and electrical switching duties are supported?


Electrical switching frequency allows up to 300 cycles/hour for AC-1 and AC-3 duties with a mechanical switching endurance of 300 cycles/hour.

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail

Les données personnelles que vous nous fournissez en vous inscrivant à cette liste de diffusion seront traitées conformément à notre politique de confidentialité.