ABB 1SBL24 Contactor, 24V ac Coil, 3-Pole, 26 A 24V ac, 3 NO, 690V
- N° de stock RS:
- 253-1959
- Référence fabricant:
- 1SBL241022R8110
- Fabricant:
- ABB
Actuellement indisponible
Nous ne savons pas si cet article sera de nouveau disponible. RS a l'intention de le retirer de son assortiment sous peu.
- N° de stock RS:
- 253-1959
- Référence fabricant:
- 1SBL241022R8110
- Fabricant:
- ABB
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ABB | |
| Coil Voltage | 24V ac | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 26A | |
| Series | 1SBL24 | |
| Function | Control Unit | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 24V ac | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 2A | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 70°C | |
| Width | 54mm | |
| Depth | 90mm | |
| Standards/Approvals | EU Directive 2011/65/EU RoHS Status | |
| Length | 94mm | |
| Pole and Throw Configuration | 3P | |
| Sélectionner tout | ||
|---|---|---|
Marque ABB | ||
Coil Voltage 24V ac | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 26A | ||
Series 1SBL24 | ||
Function Control Unit | ||
Mount Type DIN Rail | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 24V ac | ||
Contactor Application Control Unit | ||
Operational Current Ie 2A | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 70°C | ||
Width 54mm | ||
Depth 90mm | ||
Standards/Approvals EU Directive 2011/65/EU RoHS Status | ||
Length 94mm | ||
Pole and Throw Configuration 3P | ||
- Pays d'origine :
- BG
ABB UA26 Series Contactor, 16A Contact Current, 24VAc Coil Voltage - 1SBL241022R8110
This contactor is a three‑pole control unit designed for switching capacitor banks in industrial electrical systems. It operates from an AC control circuit and is intended for DIN‑rail installation in control panels. The device is suitable where controlled engagement of capacitors is required while managing inrush peaks and frequent switching cycles.
Features & Benefits
• 3P switching limits contacts to three main poles for capacitor control
• 16A conventional thermal current supports moderate load switching
• 24V AC control circuit enables common low‑voltage panel integration
• Accepts Peak inrush up to 100x nominal rms current protecting banks
• 3600 cycles per hour mechanical frequency for high switching rates
• 16A conventional thermal current supports moderate load switching
• 24V AC control circuit enables common low‑voltage panel integration
• Accepts Peak inrush up to 100x nominal rms current protecting banks
• 3600 cycles per hour mechanical frequency for high switching rates
Applications
• Suitable for staged capacitor bank switching in power factor correction
• Ideal for motor control centres requiring reactive power management
• used with low‑voltage distribution panels for load compensation
• Can be used for retrofit replacement in existing contactor arrays
• Ideal for motor control centres requiring reactive power management
• used with low‑voltage distribution panels for load compensation
• Can be used for retrofit replacement in existing contactor arrays
What Terminal types are provided for connection?
Screw terminals are supplied for both main and auxiliary circuits, with Pozidriv screws and cable clamps for secure terminations.
How does the product perform at elevated ambient temperatures?
It maintains rated operational powers with reduced kvar capacities as temperature rises, with specific permitted kvar values defined up to 70°C near the device.
What protection and fuse recommendations apply?
Auxiliary circuits are compatible with gG fuses and recommended short‑circuit protective devices range to match operational currents specified for different voltages.
What mechanical and electrical durability can be expected?
When capacitors are discharged to ≤50V before re‑energisation, electrical endurance reaches 100000 operating cycles with a block‑type pole design.
Liens connexes
- ABB UA26 Contactor 3-Pole 3 NO, 690V
- ABB UA26 Contactor 3-Pole 3 NO, 690V
- ABB UA26 Contactor 120 V Coil 6 A 110V 690V
- Lovato BF26 Contactor 3-Pole 51 kW, 690V
- Lovato BF Contactor 3-Pole 18.5 kW 24V dc 690V ac
- ABB UA26 Contactor 400 V Coil 10 A 400V 3 NO, 690V
- Allen Bradley 100C Contactor 3-Pole 26 kW 24V dc 690V ac
- Allen Bradley 100S-C Contactor 3-Pole 26 kW 24V dc 690V ac