Lovato Electric BF Contactor, 230V ac Coil, 4-Pole, 90 A, 22 kW 230V ac, 4 NO, 660 V dc, 690V ac
- N° de stock RS:
- 188-1544
- Référence fabricant:
- BF50T4A230
- Fabricant:
- Lovato
Sous-total (1 unité)*
254,61 €
(TVA exclue)
308,08 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 5 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Unité | Prix par unité |
|---|---|
| 1 + | 254,61 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 188-1544
- Référence fabricant:
- BF50T4A230
- Fabricant:
- Lovato
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Lovato | |
| Coil Voltage | 230V ac | |
| Product Type | Contactor | |
| Number of Poles | 4 | |
| Contact Voltage | 660V dc, 690V dc | |
| Contact Current | 90A | |
| Power Rating | 22kW | |
| Series | BF | |
| Function | Motor Control | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 230V ac | |
| Operational Current Ie | 50A | |
| Contactor Application | Motor Control | |
| Minimum Operating Temperature | -50°C | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | CSA, IEC, UL | |
| Length | 73mm | |
| Width | 114.6mm | |
| Depth | 136mm | |
| Pole and Throw Configuration | 4PST | |
| Sélectionner tout | ||
|---|---|---|
Marque Lovato | ||
Coil Voltage 230V ac | ||
Product Type Contactor | ||
Number of Poles 4 | ||
Contact Voltage 660V dc, 690V dc | ||
Contact Current 90A | ||
Power Rating 22kW | ||
Series BF | ||
Function Motor Control | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 230V ac | ||
Operational Current Ie 50A | ||
Contactor Application Motor Control | ||
Minimum Operating Temperature -50°C | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals CSA, IEC, UL | ||
Length 73mm | ||
Width 114.6mm | ||
Depth 136mm | ||
Pole and Throw Configuration 4PST | ||
- Pays d'origine :
- IT
Lovato Series BF Contactor, 4 Poles, 90A Contact Current Rating - BF50T4A230
Features & Benefits
Applications
What are the operational limits in terms of temperature for this device?
How does the contactor handle high current loads?
What makes this contactor suitable for photovoltaic applications?
How can the connections be secured for optimal performance?
Liens connexes
- Lovato BF Contactor 4-Pole 4 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 45 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 5.5 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 7.5 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 13 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 30 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 18.5 kW 230V ac 660 V dc, 690V ac
- Lovato BF Contactor 4-Pole 22 kW 24V ac 660 V dc, 690V ac