ABB, TA200DU-175-V1000 Thermal Overload Relay 1 NO/1 NC, Trip Dial: 130 → 175 A, 175A Contact Rating 3
- N° de stock RS:
- 258-9412
- Référence fabricant:
- 1SAZ421301R1005
- Fabricant:
- ABB
Indisponible
RS n'aura plus ce produit en stock.
- N° de stock RS:
- 258-9412
- Référence fabricant:
- 1SAZ421301R1005
- Fabricant:
- ABB
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ABB | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 175A | |
| Series | TA200DU-175-V1000 | |
| Pole and Throw Configuration | 3 | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Automatic or Manual | |
| IP Rating | IP20, IP00 | |
| Adjustable Current Range | 130 → 175 A | |
| Width | 104mm | |
| Minimum Operating Temperature | -5°C | |
| Number of Auxiliary Contacts | 1 | |
| Maximum Operating Temperature | 40°C | |
| Length | 126mm | |
| Contact Voltage | 500V | |
| Depth | 126mm | |
| Standards/Approvals | UL 60947-4-1, IEC/EN 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-1 | |
| Supply Voltage | 440V, 690V | |
| Sélectionner tout | ||
|---|---|---|
Marque ABB | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 175A | ||
Series TA200DU-175-V1000 | ||
Pole and Throw Configuration 3 | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Automatic or Manual | ||
IP Rating IP20, IP00 | ||
Adjustable Current Range 130 → 175 A | ||
Width 104mm | ||
Minimum Operating Temperature -5°C | ||
Number of Auxiliary Contacts 1 | ||
Maximum Operating Temperature 40°C | ||
Length 126mm | ||
Contact Voltage 500V | ||
Depth 126mm | ||
Standards/Approvals UL 60947-4-1, IEC/EN 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-1 | ||
Supply Voltage 440V, 690V | ||
- Pays d'origine :
- BG
1SAZ421301R1005
The ABB thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure.
It has trip class 10A
Temperature compensation feature
Automatic or manual reset selectable
Trip-free mechanism
Liens connexes
- ABB Trip Dial: 150 → 200 A 200 A Contact Rating 3
- Eaton Trip Dial: 0 → 175 A 35 A F.L.C, 175A Contact Rating
- ABB Thermal Overload Relay 1 NO/1 NC 130A 175A Contact Rating, 440V dc 3
- Eaton Contactor Relay 1 NO/1 NC 175A Contact Rating, 1kV
- ABB Trip Dial: 80 → 110 A 80 A Contact Rating 3
- ABB Trip Dial: 100 → 135 A 135 A Contact Rating 3
- Siemens Overload Relay, Trip Dial: 0.32 → 1.25 A
- Siemens Trip Dial: 12.5 → 50 A, 50A Contact Rating