Omron, J7TKN Thermal Overload Relay 1 NO/1 NC, Trip Dial: 8 → 11 A, 10A F.L.C, 44.419kA Contact Rating, 44.301 kW, 690V
- N° de stock RS:
- 214-7772
- Référence fabricant:
- J7TKN-A-11
- Fabricant:
- Omron
Sous-total (1 unité)*
63,88 €
(TVA exclue)
77,29 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- Expédition à partir du 12 janvier 2027
Unité | Prix par unité |
|---|---|
| 1 + | 63,88 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 214-7772
- Référence fabricant:
- J7TKN-A-11
- Fabricant:
- Omron
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Omron | |
| FLC Motor Rating | 10A | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 44.419kA | |
| Series | J7TKN | |
| Mount Type | Direct | |
| Power Rating | 44.301kW | |
| Pole and Throw Configuration | 3P | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Manual | |
| Minimum Operating Temperature | -25°C | |
| Width | 45mm | |
| Number of Auxiliary Contacts | 2 | |
| Adjustable Current Range | 8 → 11 A | |
| Maximum Operating Temperature | 60°C | |
| Contact Voltage | 690V | |
| Length | 95mm | |
| Depth | 70mm | |
| Standards/Approvals | VDE 0660, UL, EN/IEC 60947-4-1, IEC 60947-4-1 | |
| Control Voltage | 690V ac | |
| Sélectionner tout | ||
|---|---|---|
Marque Omron | ||
FLC Motor Rating 10A | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 44.419kA | ||
Series J7TKN | ||
Mount Type Direct | ||
Power Rating 44.301kW | ||
Pole and Throw Configuration 3P | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Manual | ||
Minimum Operating Temperature -25°C | ||
Width 45mm | ||
Number of Auxiliary Contacts 2 | ||
Adjustable Current Range 8 → 11 A | ||
Maximum Operating Temperature 60°C | ||
Contact Voltage 690V | ||
Length 95mm | ||
Depth 70mm | ||
Standards/Approvals VDE 0660, UL, EN/IEC 60947-4-1, IEC 60947-4-1 | ||
Control Voltage 690V ac | ||
Omron J7TKN Series Thermal Overload Relay, 8 to 11A Adjustable Current Range, 690V Contact Voltage - J7TKN-A-11
Features and Benefits:
• Manual reset mechanism for controlled restart after trip
• Rated for 690V operation enabling high-voltage applications
• Three-pole configuration delivering phase-by-phase disconnect capability
• Two auxiliary contacts 1NO1NC for signalling and interlock functions
• Suitable for motors up to 44.301kW based on relay rating
Applications
• Used with contactors in automated motor control panels
• Ideal for retrofit protection in manufacturing plant motor circuits
• Can be used for motor overload supervision in HVAC systems
• Used for safeguarding pumps and compressors in process lines
What environmental temperatures can it tolerate during operation?
How does the relay Interface electrically with control systems?
What standards guide its electrical and safety performance?
How is the relay physically mounted and what are its form-factor considerations?
Liens connexes
- Omron 10A F.L.C 0.9 A Contact Rating 690V ac 3P
- Omron 10A F.L.C 600V 3P
- Omron 1.8A 2.7A Contact Rating 3P
- Omron 10A 14A Contact Rating, 15 kW 3P
- Omron 1.8A 2.7A Contact Rating, 15 kW 3P
- Omron 1.2A 1.8A Contact Rating, 15 kW 3P
- Omron 0.8A 1.2A Contact Rating, 24V dc 3P
- Omron 0.6A 900mA Contact Rating, 24V dc 3P
