Phoenix Contact PSR-CT-M-SEN-1-8 Series RFID Non-Contact Safety Switch, 24V dc, Polybutylene Terephthalate Housing, M12
- N° de stock RS:
- 190-8417
- Référence fabricant:
- 2702975
- Fabricant:
- Phoenix Contact
3 En stock, livraison sous 1 jour(s) (stock Europe)
7 En stock, livraison sous 3 à 5 jours (stock Europe)
Ajouté
Prix la pièce
110,39 €
(TVA exclue)
133,57 €
(TVA incluse)
Unité | Prix par unité |
1 + | 110,39 € |
- N° de stock RS:
- 190-8417
- Référence fabricant:
- 2702975
- Fabricant:
- Phoenix Contact
Documentation technique
Législations et de normes
- Pays d'origine :
- DE
Détails du produit
Proximity safety circuit, multicode sensor with RFID coding, model 4, automatic or manual start, integrated diagnostics, 24 V DC supply, M12 connector.
The PSR-CT safety circuit consists of a combination of a PSR-CT-...-SEN-1-8 sensor with varying coding types and a coded PSR-CT-C-ACT actuator. It provides maximum tamper protection and the highest level of safety. The PSR-CT safety circuit is available with the following types of coding:
Fixcode: For the sensor to detect the actuator, the actuator must first be associated with the sensor via a learning process. The learning process can only be completed once. The sensor and actuator are then permanently assigned to each other by their coding. Safety circuits with fixcode evaluation achieve a high coding level.
Unicode: For the sensor to detect the actuator, the actuator must first be assigned to the sensor via a learning process. The learning process for a new actuator can be repeated any number of times. The sensor only detects the last learned actuator. Safety circuits with unicode evaluation achieve a high coding level.
Multicode: The sensor detects every actuator of the approved type. No specific actuator code can be assigned. Safety circuits with multicode evaluation achieve a low coding level.
The PSR-CT safety circuit consists of a combination of a PSR-CT-...-SEN-1-8 sensor with varying coding types and a coded PSR-CT-C-ACT actuator. It provides maximum tamper protection and the highest level of safety. The PSR-CT safety circuit is available with the following types of coding:
Fixcode: For the sensor to detect the actuator, the actuator must first be associated with the sensor via a learning process. The learning process can only be completed once. The sensor and actuator are then permanently assigned to each other by their coding. Safety circuits with fixcode evaluation achieve a high coding level.
Unicode: For the sensor to detect the actuator, the actuator must first be assigned to the sensor via a learning process. The learning process for a new actuator can be repeated any number of times. The sensor only detects the last learned actuator. Safety circuits with unicode evaluation achieve a high coding level.
Multicode: The sensor detects every actuator of the approved type. No specific actuator code can be assigned. Safety circuits with multicode evaluation achieve a low coding level.
Spécifications
Attribut | Valeur |
---|---|
Supply Voltage | 24V dc |
Housing Material | Polybutylene Terephthalate (PBT) |
Connection Type | M12 |
Actuator Type | Magnetic |
Safety Category | 4 |
Sensor Principle | RFID |
Switching Distance | 140 (Between Two Safety Circuits) mm, 7 (Between Sensor and Actuator when Traveling in the Y-Direction) mm |
Series | PSR-CT-M-SEN-1-8 |
IP Rating | IP65, IP67, IP69, IP69K |
Supply Current | 40mA |
Depth | 40mm |
Width | 18mm |
Length | 26.5mm |